Number of the records: 1  

Porovnanie testov na stanovenie rezíduí antibiotík v mlieku

  1. TitlePorovnanie testov na stanovenie rezíduí antibiotík v mlieku / Tatiana Žilková ; školiteľ Peter Zajác
    Author-s Žilková, Tatiana (Author)
    Zajác, Peter, ; SPUFBP05 (Thesis advisor)
    Corporation Slovenská poľnohospodárska univerzita (Nitra, Slovensko). Fakulta biotechnológie a potravinárstva. Katedra hygieny a bezpečnosti potravín
    Published2011
    Description73 s. : ilustr., tab. ; 30 cm
    NotesBibliografia s. 70-73 . Resumé anglicky, slovensky . Diplomová práca (Ing.). - Katedra hygieny a bezpečnosti potravín FBP SPU v Nitre
    Subject-s antibiotiká rezistencia voči antibiotikám reziduá liečiv detekcia (chémia) laboratórne testy mlieko kontrola potravín diplomové práce
    AnnotationAutorský abstrakt: V našej práci sme porovnávali detekčné limity antibiotík Amoxicilín, Tetracyklín a Sulfónamid u rýchlych testov Twinsensor, Eclipse a Delvotest s výsledkami detekčných limitov našej práce. Pri stanovení Amoxicilínu testom Twinsensor sme zachytili tie isté koncentrácie ako udáva výrobca. Výrobca testu Eclipse udáva DL Amoxicilínu 4 μg.l-1. Výsledok môjho pokusu bol nejednoznačný, keďže mi vzorka o koncentrácii 4 μg.l-1 vyšla dubiózne. Výrobca Delvotestu uvádza vo svojich materiáloch DL Amoxicilínu 3 μg.l-1, avšak pri našom pokuse zachytil už 2 μg.l-1. Výrobca Twinsensoru uvádza detekčný limit testu na Tetracyklín 40-50 μg.l-1. Pri našom pokuse nám vyšla pozitívne už koncentrácia 30 μg.l-1. Výrobca rýchleho testu Eclipse uvádza DL testu na Tetracyklín 100 μg.l-1. Avšak pri našom stanovení nám vyšla pozitívne už vzorka s koncentráciou 90 μg.l-1. Pri stanovení Sulfónamidu testmi Twinsensor a Delvotest nám zachytili všetky tri vzorky o koncentrácii 20, 50 a 100 μg.l-1 pozitívne. Výsledky nemôžeme porovnať s DL danými výrobcom, pretože ich neudáva. Vzorky, ktoré sme testovali testom Eclipse 50 vyšli v oboch koncentráciách (100, 200 μg.l-1) negatívne, zatiaľ čo výrobca udáva detekčný limit 100 μg.l-1. Takisto sme porovnávali detekčné limity vybraných rýchlych testov na stanovenie antibiotík v mlieku s EÚ-MRL.
    Autorský abstrakt: In our work we were comparing the detection limits of antibiotics Amoxicilin, Tetracyklin and Sulfonamid by the screening test Twinsensor, Eclipse and Delvotest with the results of detection limits of our work. In determining of Amoxicilin with Twinsensor test we have recorded the same concentrations that are stated by the manufacturer. Developer of Eclipse test state DL of Amoxicilin up to 4 μg.l-1. The result of my experiment was unambiguous because the sample with concentration of 4 μg.l-1 appeared to be dubiose. Manufacturer of Delvotest states in his own materials DL of Amoxicilin to 3 μg.l-1 but in our test we already detected the value of 2 μg.l-1. Developer of Twinsensor test states the detection limit of the test on Tetracyklin from 40 to 50 μg.l-1. In our experiment we already found out positive concentration of 30 μg.l-1. Developer of screening test Eclipse states DL of Tetracyklin test up to 100 μg.l-1. But in our experiment we already found out positive concentration of 90 μg.l-1. In determination of Sulfonamid by te tests of Twinsensor and Delvotest we was able to catch all three samples with positive results with values 20, 50 and 100 μg.l-1. We can not compare the results with DL statet by the manufacturer because he did not quote them. The samples tested by the Eclipse test 50 appeared in both concetrations (100, 200 μg.l-1) negative while the manufacturer quoted the detection limit up to 100 μg.l-1. We were also comparing the detection limits of selected screening tests to specify amount of antibiotics in milk with EÚ-MRL.
    CountrySlovakia
    LanguageSlovak
    URLezp_hlavny_text
    Copies1, available for regular loan 0, in-library use only 1
    DatabaseGraduate theses
    book

    book

    Call numberDislocationCollection in study roomAvailable
    VP-73409Skladin-library use only

Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.